Refrigerant Type: | Freon |
---|---|
Voltage: | 220-240V |
Freequency: | 50Hz |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(1)After removing the rubber plug, the compressor must be assembled with 15 mins, to avoid dirt and moisture entering.
(2)When the compressor is sotred ,transported installed, it shall not be tilted or turned upside down to avoid collision.
(3)When the compressor is working, it should be placed horizontally with the ground.The inclination angle of the compressor should not be more than 5°.
(4)The compressor is filled with the optimum amount of refrigeration oil approved by Donper. Do not piur out, add or change oil at will.
(5)To ensure the system pressure balance, the compressor running time should be less than 4 mins.
(6)Compressor can not withstand high voltage or start, operation in Vaccum condition, it cannot be used to vacuum the system.
(7)When the refrigeration system is designed, the oil return of the system should be fully considered.
(8)The working ambient temperature of normal compressor should be no more than 43ºC. When the compressor is continuously running at the highest room temperature, the condensing pressure and highest in peak pressure should not exceed the following table value(for special adaptive environment, we need to be told in advance before model selection)